How reliable is your SIL verification actually?

Keywords: IEC 61508, IEC 61511, Failure rate data, Certification, FMEDA, Verification

This article is available in:  English. Please login to request translation.


Abstract:

Nowadays most process plants are being built according the IEC standards for functional safety. The IEC 61511 standard describes various methods to determine the required risk reduction of Safety Instrumented Functions (SIF's) based upon the actual risk associated with a certain hazard scenario and the tolerable risk criteria. The required risk reduction of a SIF has to be confirmed by a Safety Integrity Level (SIL) verification calculation. How reliable is this calculation actually ?

The objective of this paper is to give the reader a better understanding of the possible pitfalls in the SIL verification calculation. The paper will first discuss the reliability requirements of the IEC standards on Functional Safety, which leaves space for different implementations. Secondly, it will discuss the reliability of the failure rate data as supplied by the instrument vendors or third parties, which are sometimes too good to be true. Thirdly, the paper will discuss the reliability of the Failure Modes, Effects and Diagnostic Analysis (FMEDA) for components, which are located in the harsh environment of a process plant. Fourthly, the paper will discuss what the required reliability of the SIL verification should be and how to obtain that. Finally the concluding remarks are presented. © 2010 Inside Publishing. All Rights Reserved.

Volume: 2010   Issue: 1
EUR 6.88
(Pages: 10, Words: 4586)

Readers of this article also bought

Other articles by André Fijan:

Articles by keywords

2oo4d accident accidents accumulative risk actuators alarm annunciator alarp ansi/isa s.84 api 521 architecture asil asset management audit automatic code generation automatic documentation automotive availability bayesian updating bpcs buncefield burner management system caex certification common cause common cause failures communication compliance component failure analysis consequence matrix content management control cost reduction cost-benefit analysis cots demand mode diagnostic coverage diagnostics digital valve controller documentation emc emergency shutdown system emi en 50402 en 746 en/iec 60079–29–1 failure incident failure rate data failure rates fieldbus fire and gas fired equipment fmeda foundation sif full stroke functional modules functional safety functional safety management gas detection gas sensors gas turbine global risk hardware hazard and operability analysis hazard and operability study hazop hazop templates heterogeneous hipps iec 61131 iec 61131-3 iec 61508 iec 61511 iec 62061 iec 61508 incident investigation independent protection layer instrumentation and control iso 26262 knowledge-based system layer of protection layer of protection analysis life cycle lifecycle management liquiphant lock-up valve lopa management management of change markov memory metrological standards microcontroler mttfs namur 93 nfpa 72 oem online changes operator over spill protection overspeed protection p&id flowchart paag partial stroke partial stroke testing pha prior use process hazop process risk process safety proof test interval proof testing proven in use qs9000 quality data quality management redundancy regulations reliability reliability data reliability engineering reliability program requirements definition review risk graphs risk matrix risk reduction risk reduction factor rule-based system safe-t-core safeguard safety safety goal safety instrumented function safety instrumented system safety instrumented systems safety integrity level safety lifecycle self-declaration sensor poisoning sif signature test sil sil determination methods sil evaluation sil-capability silstroke sil verification sis sis design software solenoid valves spurious trip standardisation state transition modelling sulphur recovery tank farm test bench texas city thermal burner third party tier 1 tolerable risk training tridefine type testing valve testing valves vdi 2180 verification