FSTalk with Reinhold Bietzker

Keywords: Liquiphant, IEC 61508, SIL, verification, Texas City, Buncefield, diagnostics, Proven in use, Tank farm, Over spill protection, Lifecycle management, Asset management

This article is available in:  English. Please login to request translation.


Abstract:

IFS: Can you tell us a bit about the kinds of products and services Endress+Hauser are involved in, as well as the relation to functional safety.

Reinhold Bietzker: Well, for a start, Endress+Hauser is a company producing a very wide range of products, starting with level, where we started off in 1953, overflow, temperature, liquid analyses and flow measurements. All devices of Endress+Hauser are designed according to the IEC 61508 regulations. The idea is to provide our customers with a big range of instruments so that they have everything available form one supplier for the normal operation of a process but also for the functional safety part. For that we need to have both the simple as well as the advanced instruments which are positioned at the critical points to prevent accidents, to prevent environmental impact and to make sure that the process is running safe and reliable.

Volume: 2010   Issue: 1
(Pages: 6, Words: 2510)

Articles by keywords

2oo4d accident accidents accumulative risk actuators alarm annunciator alarp ansi/isa s.84 api 521 architecture asil asset management audit automatic code generation automatic documentation automotive availability bayesian updating bpcs buncefield burner management system caex certification common cause common cause failures communication compliance component failure analysis consequence matrix content management control cost reduction cost-benefit analysis cots demand mode diagnostic coverage diagnostics digital valve controller documentation emc emergency shutdown system emi en 50402 en 746 en/iec 60079–29–1 failure incident failure rate data failure rates fieldbus fire and gas fired equipment fmeda foundation sif full stroke functional modules functional safety functional safety management gas detection gas sensors gas turbine global risk hardware hazard and operability analysis hazard and operability study hazop hazop templates heterogeneous hipps iec 61131 iec 61131-3 iec 61508 iec 61511 iec 62061 iec 61508 incident investigation independent protection layer instrumentation and control iso 26262 knowledge-based system layer of protection layer of protection analysis life cycle lifecycle management liquiphant lock-up valve lopa management management of change markov memory metrological standards microcontroler mttfs namur 93 nfpa 72 oem online changes operator over spill protection overspeed protection p&id flowchart paag partial stroke partial stroke testing pha prior use process hazop process risk process safety proof test interval proof testing proven in use qs9000 quality data quality management redundancy regulations reliability reliability data reliability engineering reliability program requirements definition review risk graphs risk matrix risk reduction risk reduction factor rule-based system safe-t-core safeguard safety safety goal safety instrumented function safety instrumented system safety instrumented systems safety integrity level safety lifecycle self-declaration sensor poisoning sif signature test sil sil determination methods sil evaluation sil-capability silstroke sil verification sis sis design software solenoid valves spurious trip standardisation state transition modelling sulphur recovery tank farm test bench texas city thermal burner third party tier 1 tolerable risk training tridefine type testing valve testing valves vdi 2180 verification